Drive innovation with user needs and technological R & D to promote industry progress
Skoda portable AC charging pile test and measurement comprehensive instrument PEV7001 has interoperability test and measurement verification function test. It is mainly used for the interoperability function verification, charging sequence working condition detection and measurement verification function of newly installed AC charging pile, AC charging pile after maintenance, and AC charging pile after upgrading and modification. The comprehensive instrument has the characteristics of high precision, small size, light weight, easy to carry, etc. It can meet the measurement and performance tests in various occasions such as laboratory and field. The comprehensive instrument has a measurement module that meets the measurement verification regulations of "JJG 1148-2018 Electric Vehicle AC Charging Pile", and can verify voltage error, current error, power error, working error, indication error, payment amount error, and clock indication error. Built-in software function module realizes the test item "GB / T 34657.1-2017 Electric Vehicle Conductive Charging Interoperability Test Specification Part 1 Power Supply Equipment" and has two 63A standard charging gun sockets, and the pin definition meets GB / T 20234.2-2015 Requirements.
● It has the functions of metrological verification, interoperability specification test, and vehicle interface simulation test.
● Equipped with LAN interface, RS232 interface, USB interface, WIFI interface, 4G interface.
● The test report data can be uploaded to the enterprise to the server system through the 4G network.
● With external battery terminals to meet the external power supply needs.
● It has special instrument calibration terminals to meet the laboratory calibration requirements of the comprehensive instrument.
● It has terminals for stub-end signals such as voltage, current, CP signal, hardware synchronization signal, etc. It can be connected to other test instruments to test and check the pile-end signals
● When measuring, the load is allowed to connect to the real vehicle or any simulated load
● It has the function of detecting the ambient temperature, calculates the error caused by the temperature according to the actual working scene temperature, and judges the measurement result.
● With GPS time synchronization function, the charger can be tested for Beijing time synchronization error.
● It has a charging sequence test interface, which can be connected to pile-end signals such as emergency stop switch actions to meet interoperability test specifications.
● With 6-channel timing synchronization measurement function, it can meet the interoperability test related timing tests, such as T1, TI ’, T2, T2’, T3, T3 ’, T3”, T2-T2 ’time, etc.
● Built-in vehicle end R2 resistance, R3 resistance simulation equivalent resistance simulation function, R2 resistance adjustment range 5002 ~ 40000, resistance value is continuously adjustable online, adjustment fineness 19, R3 equivalent resistance nominal value 14002 ~ 80002, resistance value online
Continuously adjustable with a fineness of 10. Each contact has an on-off switch, which can realize the simulation of the on-off state of the contact.
● It has the function of measuring the voltage, current and CP signal of the AC charging pile.
● Built-in standard national standard test items, automatic testing and report generation of the set-up procedures to facilitate changes and upgrades of national standard items.
● The comprehensive instrument has the function of generating a test report template, and generates a test report format according to the customer's layout format. The report format can be TXT, EXECL, XLC, WORD.
● Test report Support multiple data export methods: U disk direct export, computer host computer export via WIFI connection device, and 4G. Upload to the enterprise database platform.
● National standard test item, sub-modular test function, network data interface, support cross-platform calling.
● The input and output standard data of the test module of the comprehensive instrument software platform is structured, and the analysis and calling are convenient. The integrated instrument has a 10-inch high-definition LCD touch screen, which is convenient for users to touch and operate.